JIANA ZHILIAN Circular Connectors · Dongguan, China
Product family

M-Series Circular Connectors

Seven shell sizes sharing one screw-locking idea: M5 through M23 covers everything from a 3-pin proximity sensor to a 630 V servo drive. The interface is fixed by IEC 61076-2-x, so choosing between them is a design decision rather than a supplier preference — this page is the short version of that decision.

  • 13 released part numbers
  • Made to drawing
  • MOQ 500 pcs
  • Sample 3–5 days
Selection guide

How to choose an M-series part

Work down these five questions in order. Each one eliminates shells, and by the bottom you should be looking at one or two part numbers.

  1. Count the conductors — then check what the count does to the rating

    Contacts are the constraint, not the shell. Past four positions the contact diameter shrinks and the rating drops with it: an M12 A-coded body is 4 A per contact at 4-pin, but only 2 A at 5- or 8-pin. Always specify the lowest pole count that carries the signal, and re-read the current figure after you add a conductor.

  2. Let the voltage pick the shell

    24 V control circuits live happily in M8 and M12. Above 125 V, or on any drive application, the choice collapses to M23 — it is the only part in this family rated for 630 V. Putting drive voltage through an M12 is the second most common mistake after the 5-pin derating.

  3. Decide how sealed it has to be — and get the depth in writing

    IP67 is 30 minutes at 1 m. IP68 is continuous immersion at a depth and duration the supplier has to state; "IP68" printed alone is not a specification. If the joint is washed down, sits in a puddle, or a hose is pointed at it, ask for the test depth on the report. IP67 does not cover any of those.

  4. Specify the panel half before the cable half

    The receptacle decides the panel cut-out, the fixing thread and the maximum wall thickness, so it drives the enclosure drawing and has the longer lead time. Both halves use the M16×1.5 fixing thread and a Ø16.1 mm panel hole with a flat — the difference is entirely which side the nut ends up on.

  5. Match the jacket to the movement, not to the price

    PVC is fine on a static run inside a cabinet. Anything in a cable chain, on a robot joint or outdoors should be PUR — not only for abrasion, but because the temperature window widens from −25…+85 °C to −40…+105 °C on the same M12 body. State the bend radius you need and we will confirm the cable against it.

Released parts

Part numbers in this family

Comparison

Every M-series part, side by side

Ratings are per contact unless stated. A dash means the figure is not part of that part's published specification — not that it is unlimited.

PartInterfacePolesCurrentVoltageIPCyclesPick it for
M5-A3M5×0.531 A60 VIP67≥ 100Smallest sensor, gripper feedback
M8-A3M8×134 A60 VIP67≥ 100The default PNP/NPN sensor plug
M8-A4M8×144 A60 VIP67/68≥ 100IO-Link in an M8 footprint
M8-A6M8×162 A30 VIP67≥ 100Dual output, hall feedback
M9-A4M9×0.544 A125 VIP67≥ 500Instrument retrofit, encoders
M12-A4/A5M12×1 A4 / 54 A / 2 A250 V / 60 VIP67/68≥ 100Sensor or IO-Link, volume part
M12-A8M12×1 A82 A30 VIP67≥ 100Signal cluster on one gland
M12-B5M12×1 B54 A60 VIP67≥ 100PROFIBUS DP / DeviceNet drop
M12-PFM12 receptacle3/4/5/8 A, 4 D, 8 X——IP67—Front mount, no rear access
M12-PRM12 receptacle4/5/8 A, 4 D, 8 X——IP67—Flush face, 1–4 mm wall
M16-A12M16×0.75123 A60 VIP67≥ 500Interlock and control bundle
M17-A19M17192 A60 VIP67≥ 500Dense signal, fixed install
M23-A19PM23×11910 A630 VIP67≥ 500Servo power and feedback

Panel receptacles take their rating from the insert fitted, so the current and voltage cells are blank for those two part numbers. Send the coding and pole count and we quote against the matching insert.

Reference

M12 codings — and why they will not cross-mate

The coupling thread on every M12 is identical: M12×1. What changes is the keyway position and the number of contacts, which is deliberate — a fieldbus lead must not fit a sensor port, and a 400 V power lead must not fit either.

CodingKeywayDesigned forPolesTypical rating
AStraightSensors, actuators, IO-Link3–17250 V / 4 A (4-pin)
BOffsetPROFIBUS DP, DeviceNet560 V / 4 A
DOffsetIndustrial Ethernet, 100 Mbit4250 V / 4 A
XOffsetGigabit Ethernet850 V / 0.5 A
SOffsetAC power3 + PE630 V
KOffsetAC power, higher current4 + PE630 V / 12 A
TOffsetDC power3 + PE63 V / 12 A
LOffsetDC power, 5-pole4 + FE63 V / 16 A

A, B, D and X are the codings in our released receptacle range. S, K, T and L are built to order on the same shell — treat the ratings as the standard envelope and confirm against the insert datasheet.

Reference

A-coded pin assignment and conductor colours

The wiring below is the IEC 60947-5-2 convention that almost every sensor maker follows. It is here so you can read a drawing quickly, not so you can skip reading it — your device datasheet always wins.

PinFunctionConductor colourPresent on
1L+ supplyBrown3, 4, 5, 8-pin
2Second output / DI-DOWhite4, 5, 8-pin
3L− supply (0 V)Blue3, 4, 5, 8-pin
4Output 1, or IO-Link C/QBlack3, 4, 5, 8-pin
5PE, or spareGrey (green-yellow on PE parts)5, 8-pin
6–8Discrete I/OPer customer drawing8-pin only

On a 3-pin part pin 2 is absent, so the cable is brown / blue / black — not the brown / white / blue you may have seen on a 4-pin lead. Check before you crimp.

Reference

Front mount or rear mount

Both use the same coupling thread and the same panel hole, so the decision is about the enclosure, not the electrical interface.

Front mount (M12-PF)Rear mount (M12-PR)
Fix fromOutside the panelInside the panel
Visible faceHex nut and O-ringCoupling thread only, flush
Panel holeØ16.1 mm with flatØ16.1 mm with flat
Wall thicknessLimited by thread length1–4 mm standard, up to 10 mm on request
AssemblyOne hand, no rear access neededNeeds access behind the panel
SealingO-ring compressed against panelO-ring compressed against panel
Best forRetrofit, junction boxes, cabinetsCustomer-facing consoles, clean frames

The sealing band on the panel must be flat and unpainted on either type. A powder coat under the O-ring will leak, and no IP rating survives that.

Questions

Choosing between m-series circular connectors

M8 or M12 — which one do I actually need?

M8 if the sensor body is small enough that an M12 will not physically fit, or if 3–4 A per contact is enough. M12 otherwise: it is the higher-volume, lower-cost interface, it carries IO-Link, and it is what most machine builders stock. The two do not intermix, so the choice follows the device, not the cable.

Can I plug a 3-pin M8 cable into a 4-pin M8 socket?

Yes. M8 A-coded is one interface available in 3, 4, 6 and 8 positions, so the mechanics and the seal are the same. Contact 4 simply stays open — an IO-Link device will then fall back to standard SIO mode instead of failing.

Is A-coded M12 the same thing as IO-Link?

IO-Link runs on an A-coded M12 5-pin connector, but A-coded M12 is far older and wider than IO-Link — plain PNP sensors use it too. The practical consequence is the 5-pin derating: 60 V / 2 A instead of the 4-pin 250 V / 4 A.

What is the difference between IP67 and IP68?

IP67 is 30 minutes at 1 m depth. IP68 is continuous immersion at a depth and duration the supplier has to declare on the test report. A supplier who prints "IP68" with no depth has not specified anything. We state the depth on request.

Do you supply the mating half, or only the cable side?

Both. Cable plugs, panel receptacles, field-wireable bodies and PCB-pin versions come from the same insert family, so the mating pair is guaranteed to intermate. Ordering only one half is fine — we will confirm the counterpart part number.

What is the smallest order you will take?

One piece for a sample, 500 pieces for a production run at the published price. Between those, we quote per order — the setup cost of a moulded cable assembly dominates anything under a few hundred pieces.

Need something not listed?

These are the parts already in tooling. Most orders are something else — send the drawing and we will quote it the same way.

Send the drawing