JIANA ZHILIAN Circular Connectors · Dongguan, China
Technical notes

IP67 vs IP68 vs IP69K: What the Second Digit Actually Promises

IP67 is a defined test. IP68 is not — the manufacturer declares the depth and duration. IP69K is a different test entirely, aimed at a jet, not at immersion.

6 min read

The IP code has two digits. The first is solids, the second is water. Almost every industrial connector is IP6x for the first digit — dust-tight — so the argument is always about the second.

IP67 is a fixed test

Immersion in 1 m of water for 30 minutes, with the enclosure at a defined temperature differential. Every supplier testing to IP67 is doing the same thing, which is why the number is comparable between them.

IP68 is not a fixed test

IEC 60529 deliberately leaves IP68 open: the manufacturer states the depth and the duration, and “continuous immersion” has to be qualified. So one supplier’s IP68 may be 1.2 m for 24 hours and another’s may be 5 m for 7 days.

A bare “IP68” claim is not a specification. Ask two questions:

  1. What depth and duration?
  2. Can I see the test report for that depth and duration?

If the second answer is no, treat the first answer as marketing.

IP69K is a different test

IP69K is high-pressure, high-temperature jet: 80 °C water at 80–100 bar, from four angles at defined distances. It is aimed at washdown, not at immersion.

This matters because the two failures are different. Immersion loads the seal with static pressure. A jet attacks the face directly and can drive water past a seal that would hold perfectly under 5 m of static head. A connector that passes IP68 may fail IP69K, and one designed for IP69K — flush face, O-ring in a machined groove, no recessed dirt traps — usually also passes IP68.

Where each rating belongs

Environment Rating to specify
Indoor machine, occasional splash IP65
Outdoor, rain and wash with a hose IP67
Buried or submersible IP68 with a stated depth and duration
Food processing, high-pressure clean-down IP69K
Vehicle underbody, road spray IP6K9K or IP67 + vibration test

The rating only applies mated

This is the point that causes most field failures. IP67 on a circular connector means IP67 when mated, or when the protective cap is fitted. An unmated connector hanging in a washdown area is not protected, and the cap that got lost in week two is the reason water is inside the housing in month six.

If the connector will be unmated regularly in a wet area, specify a part rated for it in that state — and a tethered cap, so it stays with the equipment.

What to put on the drawing

IP67 mated per IEC 60529; IP68 variant to be declared at 1.5 m / 24 h with test report; unmated protection IP66 with cap fitted

That sentence removes every ambiguity a supplier could exploit, and it costs nothing to add.

Need this built to your drawing?

Send the drawing, the gauge and the annual volume — we quote within one working day and sign an NDA before drawings change hands.

Request a quotation

← All technical notes