M12 A-Coded 4/5-Pin Connector
M12×1 A-coded connector in 4- and 5-pin, 250 V / 4 A (4-pin) and 60 V / 2 A (5-pin), IP67/IP68, straight or 90°.
- Interface M12×1, A-coded, 4-pin or 5-pin
- Rated voltage 250 V (4-pin) / 60 V (5-pin)
- Rated current 4 A (4-pin) / 2 A (5-pin) per contact
- Contacts Ø1.0 mm brass, gold over nickel
Part reference JN-M12-A4/A5 · MOQ 500 pcs · Sample in 3–5 working days
A-coded M12 is the highest-volume industrial circular connector in the world. Four pins carry sensor supply and one output; five pins add the IO-Link C/Q line and are now the default on new machine builds.
Note the rating split: the 4-pin version is rated 250 V / 4 A, the 5-pin only 60 V / 2 A, because the fifth contact reduces the creepage distance. Specifying a 5-pin part where the 4-pin rating was assumed is the single most common M12 mistake.
Technical data
| Interface | M12×1, A-coded, 4-pin or 5-pin |
|---|---|
| Rated voltage | 250 V (4-pin) / 60 V (5-pin) |
| Rated current | 4 A (4-pin) / 2 A (5-pin) per contact |
| Contacts | Ø1.0 mm brass, gold over nickel |
| Contact resistance | ≤ 5 mΩ |
| Insulation resistance | ≥ 100 MΩ at 500 V DC |
| Mating cycles | ≥ 100 |
| Ingress protection | IP67 / IP68 (mated) |
| Temperature | −25 °C to +85 °C (PVC), −40 °C to +105 °C (PUR) |
| Cable | 4/5 × 0.34 mm² (22 AWG), 5.9 mm OD |
Typical applications
- Proximity, photoelectric and pressure sensors
- IO-Link devices (5-pin)
- Actuator and valve pilot wiring
- Robot tooling and end effectors
What we can change
- Cable length 0.3–30 m
- Straight, 90° or rotatable 90° moulded body
- Shielded version with foil + braid
- LED indicator, custom pinout, customer labelling
- Field-wireable screw or spring version
Questions about this part
Why is the 5-pin rated lower than the 4-pin?
Fitting a fifth contact into the same Ø1 mm circle reduces the spacing between live parts, so the standard caps the 5-pin version at 60 V / 2 A. If you need 250 V and 4 A, stay with 4-pin.
Does IP67 also mean IP68?
No. IP67 is 30 minutes at 1 m; IP68 is continuous immersion at a depth and duration the supplier must state. Ask for the test depth on the report — "IP68" alone is not a specification.
Other parts in this range
Send the drawing for m12 a-coded 4/5-pin connector
Attach the drawing, a sample photo with dimensions, or your target specification. We quote within one working day and sign an NDA before drawings change hands.