JIANA ZHILIAN Circular Connectors · Dongguan, China

M12 A-Coded 4/5-Pin Connector

M12×1 A-coded connector in 4- and 5-pin, 250 V / 4 A (4-pin) and 60 V / 2 A (5-pin), IP67/IP68, straight or 90°.

  • Interface M12×1, A-coded, 4-pin or 5-pin
  • Rated voltage 250 V (4-pin) / 60 V (5-pin)
  • Rated current 4 A (4-pin) / 2 A (5-pin) per contact
  • Contacts Ø1.0 mm brass, gold over nickel

Part reference JN-M12-A4/A5 · MOQ 500 pcs · Sample in 3–5 working days

A-coded M12 is the highest-volume industrial circular connector in the world. Four pins carry sensor supply and one output; five pins add the IO-Link C/Q line and are now the default on new machine builds.

Note the rating split: the 4-pin version is rated 250 V / 4 A, the 5-pin only 60 V / 2 A, because the fifth contact reduces the creepage distance. Specifying a 5-pin part where the 4-pin rating was assumed is the single most common M12 mistake.

Technical data

Interface M12×1, A-coded, 4-pin or 5-pin
Rated voltage 250 V (4-pin) / 60 V (5-pin)
Rated current 4 A (4-pin) / 2 A (5-pin) per contact
Contacts Ø1.0 mm brass, gold over nickel
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ at 500 V DC
Mating cycles ≥ 100
Ingress protection IP67 / IP68 (mated)
Temperature −25 °C to +85 °C (PVC), −40 °C to +105 °C (PUR)
Cable 4/5 × 0.34 mm² (22 AWG), 5.9 mm OD

Typical applications

  • Proximity, photoelectric and pressure sensors
  • IO-Link devices (5-pin)
  • Actuator and valve pilot wiring
  • Robot tooling and end effectors

What we can change

  • Cable length 0.3–30 m
  • Straight, 90° or rotatable 90° moulded body
  • Shielded version with foil + braid
  • LED indicator, custom pinout, customer labelling
  • Field-wireable screw or spring version

Questions about this part

Why is the 5-pin rated lower than the 4-pin?

Fitting a fifth contact into the same Ø1 mm circle reduces the spacing between live parts, so the standard caps the 5-pin version at 60 V / 2 A. If you need 250 V and 4 A, stay with 4-pin.

Does IP67 also mean IP68?

No. IP67 is 30 minutes at 1 m; IP68 is continuous immersion at a depth and duration the supplier must state. Ask for the test depth on the report — "IP68" alone is not a specification.

Next step

Send the drawing for m12 a-coded 4/5-pin connector

Attach the drawing, a sample photo with dimensions, or your target specification. We quote within one working day and sign an NDA before drawings change hands.